Lithium ion batteries are divided into square lithium batteries (such as commonly used mobile phone battery cells), cylindrical lithium batteries (such as 18650. 18500, etc.) and button lithium batteries according to their appearance; Lithium batteries are divided into aluminum shell lithium batteries, steel shell lithium batteries and soft pack batteries according to outsourcing materials: lithium cobalt oxide, lithium iron phosphate, lithium manganate and lithium polymer according to cathode materials.
1. The identification of square lithium battery consists of 3 letters + 6 numbers. See the following for each part
Battery cathode materials and types
l: There is a built-in lithium-ion battery.
L:Lithium metal electrode or lithium alloy electrode
2. Second letter
Battery cathode material
C:Drill based electrode.
N:Nickel based electrode
M:Manganese based electrode。
V:Vanadium based electrode
3. Third letter
Battery shape
R:Round battery
L: lozenge battery
4. Number
Diameter and height
Five numbers: respectively represent the diameter and height of the battery (the unit of diameter is mm and the unit of height is 0.1mm) , diameter or height -- when the dimension is greater than or equal to 100mm, a slash shall be added between the two dimensions.
6 numbers: respectively represent the thickness, width and height of the battery, in mm, and the thickness, width and height are the same
Any dimension - when one is greater than or equal to 100mm, a slash shall be added between the dimensions. Dimensions of thickness, width and height If any one is less than 1mm, add the letter T before this dimension (the unit of this dimension is 0.1mm)
For example, icl07 / 25 / 150 represents a square secondary lithium ion battery with a cathode material of and a thickness of about 7mm The width is about 25mm The height is about 150mm.
1. Global
(1)Lithium battery / mobile power un38 3 certification standards:ST/SG/AC 10/1 1/Rev.n-Section38- Amend IATA DGR
(2)Preparation and certification standard of MSDs for lithium battery / mobile power supply:ISO 11014 Safety data sheet for chemical products
2.CB Member States
CB certification
Certification standard for portable secondary cell / battery / mobile power supply:IEC62133. IEC 60950
Lithium battery / mobile power certification standard:IEC 61960
Primary cell / battery certification standard:IEC 60086
Secondary cell or battery containing alkaline or non acid electrolyte:IEC 61951
Certification standard for safe transportation of primary and secondary lithium batteries:IEC 62281
3.U.S.A
(1)UL/ETL/cTUVus certification
Lithium battery cell certification standard: UL 1642
Household and commercial battery certification standards: UL 2054, UL 60950
Mobile power supply certification standards: UL 2056, UL 60950
Battery certification standard: UL 62133
(2) CTIA certification standard for batteries for communication products: IEEE 1725, IEEE 1625
4.China
(1)CQC certification and quality inspection report
Certification standard for portable secondary cell and battery: GB31241
Mobile power certification standard: GB / T 35590
Certification standard of primary battery (pack): GB / T 8897
Certification standard for lithium ion batteries and battery packs for mobile phones: GB / t18287
Certification standard for portable secondary cell and battery / mobile power supply: CNS 15364
(2) BSMI certification standard for portable secondary cell and battery / mobile power supply: CNS 15364
5.Korea
Portable secondary lithium cell / battery / mobile power KC certification standard: K 62133
6.Japan
PSE certification standard for portable secondary lithium cell / battery / mobile power supply: J 62133
7. Russia
Lithium cell / battery / mobile power GOST-R (EAC) certification standard: IEC 62133 & EMC
8.India
BIS certification
Lithium battery cell / cell pack certification standard: IS 16046
Mobile power supply certification standard: is 13252 (Part 1)
9.Thailand
TISI authentication
Certification standard for batteries and battery packs containing alkaline or other non acid electrolytes: Tis 2217-2548
Mobile power certification standard: Tis 2879-2560
Certification standard for built-in cell and battery of mobile power supply: Tis 2217 TIS 2879
10.European Union (EU)
(1)CE certification
Portable secondary cell and battery certification standards: en / IEC 62133, en / IEC 60950
Portable secondary lithium battery and battery certification standard: en / IEC 61960
Certification standard for secondary nickel cadmium and nickel hydrogen batteries: en / IEC 61951
Certification standard for primary battery (pack) / primary battery: en / IEC 60086
Lithium battery certification standard: en / IEC 62281
(2) Cell / battery / mobile power WEEE certification standard: 2012 / 19 / EU
(3) ROHS certification standard for battery / mobile power supply: 2011 / 65 / 5u
(4) Reach certification standard for battery / mobile power supply: svhc181
11.Germany
Lithium battery / mobile power GS certification standard: en 60950 & AFPs GS 2014:01pak
12.Australia
RCM certification
Portable secondary battery certification standard: as / NZS CISPR 32 as / NZS 61000-6-3
Mobile power certification standard: as / NZS CISPR 32 & en / IEC62133
13. Brazil
(1) Mobile phone battery Anatel certification standard: Anatel's Resolution 242
IEC 61960&IEC 62133&IEC 610004-2
(2) Inmetro certification standard for mobile power supply: IEC 62133
14. Mexico
Battery NOM certification standard: nom-024-scfi
15. Saudi Arabia
SASO certification standard for battery / mobile power supply: IEC corresponding standard
16. Malaysia
Lithium battery MC certification standard: IEC 60086
17.Vietnam
Lithium battery SDoC (MIC certification) certification standard: QCVN-101: 2016/BTTTT